1 - 15
Chapter1 Outline of Synchronous Control
(2) Deceleration stop
The output axis stops with deceleration according to the setting in "[Pr.37] Stop group 1
sudden stop selection" to "[Pr.39] Stop group 3 sudden stop selection". The
deceleration time is set in "[Pr.446] Synchronous control deceleration time" for
deceleration stop, and in "[Pr.36] Sudden stop deceleration time" for sudden stop. The
slope of deceleration is as follows.
Slope of deceleration =
"[Pr.8] Speed limit value"
/
Deceleration time
(Sudden stop deceleration time)
The cam axis current value per cycle is not updated, and only the feed current value is
updated, since the deceleration stop begins. Therefore, the path of the feed current
value is drawn regardless the cam operation with deceleration stop.
The input axis must be stopped when the output axis is stop synchronizing with the
input axis.
t
t
t
Deceleration stop
Axis stop signal
Cd.380 Synchronous control
start (Target axis bit)
Md.20 Feed current value
(Cam operation)
Md.22 Feedrate
Md.407 Cam axis current
value per cycle
BUSY signal
Содержание LD77MH
Страница 2: ......
Страница 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Страница 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Страница 104: ...3 20 Chapter 3 Cam Function MEMO ...
Страница 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Страница 223: ...Appendix 7 Appendices 3 Create the cam data cam No 1 4 Set the synchronous parameter of the axis 1 ...
Страница 234: ...Appendix 18 Appendices MEMO ...
Страница 237: ......