4 - 48
Chapter 4 Synchronous Control
4.6 Synchronous control change function
4.6.1 Overview of synchronous control change function
This function can change the cam reference position, the cam axis current value per cycle
and the current value per cycle after the main/auxiliary shaft gear during the synchronous
control.
The following 5 methods exist for the synchronous control change function.
Refer to Section 4.6.2 for details on each change command.
Synchronous control change
command
Application
Output axis
operation
Cam reference position movement
Adjust the cam reference position by travel value.
Operated
Change cam axis current value per
cycle
Change the cam axis current value per cycle.
None
Change current value per cycle after
main shaft gear
Change the current value per cycle after main shaft
gear.
None
Change current value per cycle after
auxiliary shaft gear
Change the current value per cycle after auxiliary
shaft gear.
None
Cam axis current value per cycle
movement
Adjust the phase of the cam axis by travel value.
Operated