![Mitsubishi Electric LD77MH Скачать руководство пользователя страница 200](http://html.mh-extra.com/html/mitsubishi-electric/ld77mh/ld77mh_user-manual_239045200.webp)
5 - 32
Chapter 5 Synchronous Control Initial Position
Example) When "[Cd.617] Cam position calculation: Cam axis current value per cycle" is
corresponding to the last point of cam data
0
(Cam reference position)
Cam axis length per cycle [Cam axis cycle units]
At the 1st point
At the 3rd point
At the 4th point
(1)
(2)
1
Search starting point
At the 0th point
Search order
At the 5th point
(3)
At the 2nd point
[Cd.617] Cam position calculation: Cam axis
current value per cycle
• Searches from the range of (3).