5 - 8
Chapter 5 Synchronous Control Initial Position
Setting item
Setting details
Setting value
Default
value
Buffer memory
address
[Pr.468]
Cam axis current
value per cycle
(Initial setting)
• Set the initial value for the cam axis
current value per cycle.
• The restoration value for the cam axis
current value per cycle is searched from
the setting value with the cam axis current
value per cycle restoration.
Fetch cycle: At start of synchronous control
Set in decimal.
0 to (Cam axis length per cycle - 1)
[Cam axis cycle units
(Note-1)
]
0
36512+200n
36513+200n
n: Axis No.-1
(Note-1): Cam axis cycle units (Refer to Section 4.5.1)
[Pr.460] Setting method of current value per cycle after main shaft gear
Select the setting method of "[Md.401] Current value per cycle after main shaft gear" when
starting synchronous control.
0: Previous value .......................................... The current value per cycle after main shaft
gear from the last synchronous control
session is stored.
1: Initial setting value of current value per cycle after main shaft gear
............................. The value set in "[Pr.465] Current value per
cycle after main shaft gear (Initial setting)" is
stored.
2: Calculate from input axis .......................... The value calculated based on the current
value after composite main shaft gear is
stored.
[Pr.461] Setting method of current value per cycle after auxiliary shaft gear
Select the setting method of "[Md.402] Current value per cycle after auxiliary shaft gear"
when starting synchronous control.
0: Previous value .......................................... The current value per cycle after auxiliary
shaft gear from the last synchronous control
session is stored.
1: Initial setting value of current value per cycle after auxiliary shaft gear
........................... The value set in "[Pr.466] Current value per
cycle after auxiliary shaft gear (Initial setting)"
is stored.
2: Calculate from input axis .......................... The value calculated based on the auxiliary
shaft current value is stored.
Содержание LD77MH
Страница 2: ......
Страница 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Страница 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Страница 104: ...3 20 Chapter 3 Cam Function MEMO ...
Страница 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Страница 223: ...Appendix 7 Appendices 3 Create the cam data cam No 1 4 Set the synchronous parameter of the axis 1 ...
Страница 234: ...Appendix 18 Appendices MEMO ...
Страница 237: ......