Chapter 4 Synchronous Control
4.7 Synchronous control monitor data
Synchronous control monitor data is updated only during synchronous control.
The monitor values ([Md.400], [Md.401], [Md.402], [Md.407], [Md.408], and [Md.409]) from
the last synchronous control session are restored the next time the system's power supply
turns ON. Restarting operation status from the last synchronous control session is possible
through returning to the last position via positioning control (Refer to Chapter 5).
"The last synchronous control session" indicates status just before the last synchronous
control session was stopped as follows. These are listed with the last synchronization status.
• Just before "[Cd.380] Synchronous control start" turns from ON to OFF.
• Just before deceleration stop by a stop command or an error, etc.
• Just before the system's power supply turned OFF to the Simple Motion module.
Monitor item
Storage details
Monitor value
Buffer memory
address
[Md.400]
Current value after
composite main shaft
gear
• The current value after combining the main input
and sub input values from the main shaft is stored.
• Value is stored even after system's power supply
OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in decimal
display.
-2147483648 to 2147483647
[Main input axis position units
(Note-1)
]
42800+40n
42801+40n
[Md.401]
Current value per cycle
after main shaft gear
• The current value per cycle after the main shaft
gear is stored.
• One cycle is considered the cam axis length per
cycle.
• Value is stored even after system's power supply
OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in decimal
display.
0 to (Cam axis length per cycle-1)
[Cam axis cycle units
(Note-2)
]
42802+40n
42803+40n
[Md.402]
Current value per cycle
after auxiliary shaft
gear
• The current value per cycle after the auxiliary shaft
gear is stored.
• One cycle is considered the cam axis length per
cycle.
• Value is stored even after system's power supply
OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in decimal
display.
0 to (Cam axis length per cycle-1)
[Cam axis cycle units
(Note-2)
]
42804+40n
42805+40n
[Md.406]
Cam axis phase
compensation amount
• The current phase compensation amount is stored.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in decimal
display.
-2147483648 to 2147483647
[Cam axis cycle units
(Note-2)
]
42810+40n
42811+40n
[Md.407]
Cam axis current value
per cycle
• The current value per cycle is stored, which is
calculated from the input travel value to the cam
axis. (The value after phase compensation)
• Value is stored even after system's power supply
OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in decimal
display.
0 to (Cam axis length per cycle-1)
[Cam axis cycle units
(Note-2)
]
42812+40n
42813+40n
n: Axis No.-1
(Note-1): Main input axis position units (Refer to Chapter 2)
(Note-2): Cam axis cycle units (Refer to Section 4.5.1)
Содержание LD77MH
Страница 2: ......
Страница 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Страница 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Страница 104: ...3 20 Chapter 3 Cam Function MEMO ...
Страница 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Страница 223: ...Appendix 7 Appendices 3 Create the cam data cam No 1 4 Set the synchronous parameter of the axis 1 ...
Страница 234: ...Appendix 18 Appendices MEMO ...
Страница 237: ......