56
CONNECTION T
O
L
S
IN
DUST
R
IA
L
SY
STEMS PLC
57
CONNECTION T
O
SI
CK SAFE
T
Y
CONTROL
LER
58
CONNE
C
T
ION T
O
SI
EME
N
S PLC
59
CON
N
ECT
ION
T
O
HI
RA
TA
C
O
RPOR
AT
ION
HN
C C
O
NT
ROL
LE
R
60
CONNECTION
T
O
MURA
TEC
CONT
ROLLE
R
61
MICROCOMPUTER
C
O
NNECTION
(SERI
A
L)
62
MICROCOMPUTER
CONNECTION
(ETHERNET)
63
MODBUS
(R)/
R
T
U
CONNECTION
63. MODBUS(R)/RTU CONNECTION
63.5 MODBUS/RTU Equipment Side Setting
63 - 9
(b) When configuring individual communication
settings for specific channel numbers
The table below shows the settings for the GS
device.
63.5.2 Station number setting
In the MODBUS network, a maximum of 31 MODBUS
equipment can be connected to one GOT.
Assign a non-overlapped station number ranging from 1 to
247 arbitrarily to each MODBUS equipment.
In the system configuration, the MODBUS equipment with
the station number set with the host address must be
included.
The station number can be set without regard to the cable
connection order. There is no problem even if station
numbers are not consecutive.
(1) Direct specification
When setting the device, specify the station number of
the MODBUS
/RTU equipment of which data is to be
changed.
(2) Indirect specification
When setting the device, indirectly specify the station
number of the MODBUS
/RTU equipment of which
data is to be changed using the 16-bit GOT internal
data register (GD10 to GD16).
When specifying the station No. from 248 to 254 on GT
Designer3, the value of GD10 to GD16 compatible to
the station No. specification will be the station No. of
the MODBUS
/RTU equipment.
(3) All station specification (broadcast)
Target station differs depending on write-in operation or
read-out operation.
• For write-in operation, all station will be a target.
• For read-out operation, only the host station will be a
target.
GS573
Function Code "03"
Specification for the max.
number of holding register
read times
0: 125
1 to 125: Specify the maximum number.
Other than above: 125
GS574
Function Code "04"
Specification for the max.
number of input register
read times
0: 125
1 to 125: Specify the maximum number.
Other than above: 125
GS575
Function Code "0F"
Specification for the max.
number of multiple-coil
write times
0: 800
1 to 1968: Specify the maximum number.
Other than above: 1968
When Bit0 of GS570 is "1", the function
code "0F" is not used, and therefore the
setting of GS575 will be disabled.
GS576
Function Code "10"
Specification for the max.
number of multiple-
holding register write
times
0: 100
1 to 123: Specify the maximum number.
Other than above: 123
When Bit1 of GS570 is "1", the function
code "10F" is not used, and therefore the
setting of GS576 will be disabled.
GS device
Description
Set value
Ch1 Ch2 Ch3 Ch4
GS
590
GS
597
GS
604
GS
611
Command selection
Bit0: 0 Using Function Code "0F"
1 Not using Function Code "0F"
Bit1: 0 Using Function Code "10"
1 Not using Function Code "10"
GS
591
GS
598
GS
605
GS
612
Function Code "01"
Specification for the
max. number of coil
read times
0: 2000
1 to 2000: Specify the maximum
number.
Other than above: 2000
GS
592
GS
599
GS
606
GS
613
Function Code "02"
Specification for the
max. number of
input relay read
times
0: 2000
1 to 2000: Specify the maximum
number.
Other than above: 2000
GS
593
GS
600
GS
607
GS
614
Function Code "03"
Specification for the
max. number of
holding register
read times
0: 125
1 to 125: Specify the maximum
number.
Other than above: 125
GS
594
GS
601
GS
608
GS
615
Function Code "04"
Specification for the
max. number of
input register read
times
0: 125
1 to 125: Specify the maximum
number.
Other than above: 125
GS
595
GS
602
GS
609
GS
616
Function Code "0F"
Specification for the
max. number of
multiple-coil write
times
0: 800
1 to 1968: Specify the maximum
number.
Other than above: 1968
When Bit0 of GS570 is "1", the
function code "0F" is not used, and
therefore the setting of GS575 will
be disabled.
GS
596
GS
603
GS
610
GS
617
Function Code "10"
Specification for the
max. number of
multiple-holding
register write times
0: 100
1 to 123: Specify the maximum
number.
Other than above: 123
When Bit1 of GS570 is "1", the
function code "10F" is not used, and
therefore the setting of GS576 will
be disabled.
GS
device
Description
Set value
Specification range
1 to 247
Specification
station NO.
Compatible
device
Setting range
248
GD10
0 to 255:
0 : All station specification (broadcast)
255 : Host station access
For the setting other than the above, an
error (dedicated device is out of range) will
occur.
249
GD11
250
GD12
251
GD13
252
GD14
253
GD15
254
GD16
GOT
Examples of station number setting
Station
No.3
Station
No.15
Station
No.1
Содержание GT14
Страница 1: ......
Страница 2: ......
Страница 34: ...A 32 ...
Страница 46: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Страница 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Страница 108: ...6 36 6 OPTION 6 7 With wall mounting Attachment ...
Страница 124: ...8 10 8 COMMUNICATION CABLE 8 2 External Cable Relay Cable ...
Страница 172: ...11 16 11 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 11 3 Ethernet Setting ...
Страница 200: ...12 28 12 DISPLAY AND OPERATION SETTINGS GOT SET UP 12 6 License Management ...
Страница 204: ...13 4 13 CLOCK SETTINGS AND BATTERY STATUS DISPLAY TIME SETTING AND DISPLAY 13 1 Time Setting and Display ...
Страница 296: ...14 92 14 FILE DISPLAY AND COPY PROGRAM DATA CONTROL 14 2 Various Data Control ...
Страница 320: ...15 24 15 GOT SELF CHECK DEBUG AND SELF CHECK 15 4 GOT start time ...
Страница 322: ...16 2 16 CLEANING DISPLAY SECTION CLEAN ...
Страница 336: ...17 14 17 INSTALLATION OF COREOS BOOTOS AND STANDARD MONITOR OS 17 5 CoreOS ...
Страница 360: ...19 8 19 MAINTENANCE AND INSPECTION 19 5 Backlight Shutoff Detection ...
Страница 382: ......
Страница 450: ...22 34 22 COMPUTER LINK CONNECTION 22 6 Precautions ...
Страница 508: ...23 58 23 ETHERNET CONNECTION 23 5 Precautions ...
Страница 526: ......
Страница 592: ...26 22 26 SERVO AMPLIFIER CONNECTION 26 7 Precautions ...
Страница 598: ...27 6 27 ROBOT CONTROLLER CONNECTION 27 6 Precautions ...
Страница 607: ...MULTIPLE GOT CONNECTION FUNCTION 29 MULTIPLE GOT CONNECTION FUNCTION 29 1 ...
Страница 608: ......
Страница 619: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Страница 620: ......
Страница 635: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Страница 636: ......
Страница 688: ...31 52 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Страница 698: ...App 10 APPENDICES Appendix 2 Usage Condition of Utility Function ...
Страница 703: ......
Страница 704: ......
Страница 705: ......
Страница 706: ......
Страница 738: ...A 32 ...
Страница 748: ......
Страница 820: ...33 44 33 CONNECTION TO OMRON PLC 33 4 Device Range that Can Be Set ...
Страница 834: ...34 14 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Страница 912: ...37 22 37 CONNECTION TO JTEKT PLC 37 7 Precautions ...
Страница 930: ...38 18 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Страница 980: ...41 16 41 CONNECTION TO TOSHIBA PLC 41 4 Device Range that Can Be Set ...
Страница 996: ...43 8 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Страница 1028: ...44 32 44 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 44 6 Device Range that Can Be Set ...
Страница 1052: ...46 10 46 CONNECTION TO HITACHI PLC 46 6 Device Range that Can Be Set ...
Страница 1092: ...47 40 47 CONNECTION TO FUJI PLC 47 5 Precautions ...
Страница 1108: ...48 16 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Страница 1142: ...49 34 49 CONNECTION TO YASKAWA PLC 49 4 Device Range that Can Be Set ...
Страница 1332: ...55 28 55 CONNECTION TO GE PLC 55 7 Precautions ...
Страница 1348: ...56 16 56 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 56 6 Device Range that Can Be Set ...
Страница 1352: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Страница 1368: ...58 16 58 CONNECTION TO SIEMENS PLC 58 4 Device Range that Can Be Set ...
Страница 1370: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Страница 1372: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Страница 1373: ...MICROCOMPUTER CONNECTION 61 MICROCOMPUTER CONNECTION SERIAL 61 1 62 MICROCOMPUTER CONNECTION ETHERNET 62 1 ...
Страница 1374: ......
Страница 1515: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Страница 1516: ......
Страница 1537: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Страница 1538: ......
Страница 1545: ......
Страница 1546: ......