9.3 Drive Control Unit
ATECH / ZAPI
•17) DRIVER 2 KO
17) DRIVER 2 KO
•If voltage at connection NT2 (A4) does not correspond to determined value, an alarm
is output and the system switches off.
•Possible causes:
•
a) Wire broken at connection NT2 (A4) or coil of forward direction contactor
is defective.
•
B) The internal MOSFET driver is short-circuited (replace controller!)
•18) DRIVER 2 SIC KO
•If current load at contactor driver controlling the output NT2 (A4) is excessive, an
alarm is output and the system switches off.
•Possible causes:
•
a) Short-circuit of the wire at connection NT2 (A4) to +Batt
•
b) Coil of connected contactor short-circuited or current consumption > 5A
64
Содержание ERIDE 30
Страница 19: ...3 Technical Data 19 ...
Страница 22: ...4 2 System Maintenance I The following maintenance work must be performed by an authorized Service Center 22 ...
Страница 23: ...4 3 System Maintenance II The following maintenance work must be performed by an authorized Service Center 23 ...
Страница 38: ...7 Mechanical Components 7 1 Squeegee Fig 7 1 38 ...
Страница 40: ...7 1 Mechanical Components 7 1 Squeegee Abb 30 Fi 7 3 Abb 30 Fig 7 2 Fig 7 3 Fig 7 2 40 ...
Страница 44: ...7 2 Forward and Reverse Switch The pictures below show the wiring of the switch 44 ...
Страница 45: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 45 ...
Страница 46: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 46 ...
Страница 76: ...11 Adjustment of Disk Brake 76 ...
Страница 80: ...12 2 Notes 80 ...