9.3 Drive Control Unit
ATECH / ZAPI
•15) DRIVER 1 KO
15) DRIVER 1 KO
•If voltage at connection NT1 (A11) does not correspond to determined value, an alarm
is output and the system switches off.
•Possible causes:
•
a) Wire broken at connection NT1 (A11) or coil of reverse direction contactor
is defective.
b) The internal MOSFET driver is short-circuited (replace controller!)
•16) DRIVER 1 SIC KO
•If current load at contactor driver controlling the output NT1 (A11) is excessive, an
alarm is output and the system switches off.
•Possible causes:
•Possible causes:
a) Short-circuit of the wire at connection NT1 (A11) to +Batt
•
b) Coil of connected contactor short-circuited or current consumption > 5A
63