9.3 Drive Control Unit
ATECH / ZAPI
•8) VMN HIGH
8) VMN HIGH
•Test in rest state;
•If contactors are open, voltage at VMN connection normally amounts to 50% VBatt. If
this voltage value is exceeded (> 70% VBatt), an alarm is output. Possible causes:
)
A di
ti
t
t
i
tl
l
d i
h
i
ll bl
k d
a)
A direction contactor is permanently closed since mechanically blocked
or permanently driven (incorrect wiring of contactor coil)
b)
Short-circuit between field and armature winding of motor
(disconnect cable at connection VMN, switch on, error disappears, repair motor)
c)
Incorrect connection of motor cable (check field and armature winding)
d)
Power circuit of controller defective (free wheeling or braking diodes short-
circuited) (disconnect cable at connection VMN, switch on, error persists,
replace controller)
p
)
59
Содержание ERIDE 30
Страница 19: ...3 Technical Data 19 ...
Страница 22: ...4 2 System Maintenance I The following maintenance work must be performed by an authorized Service Center 22 ...
Страница 23: ...4 3 System Maintenance II The following maintenance work must be performed by an authorized Service Center 23 ...
Страница 38: ...7 Mechanical Components 7 1 Squeegee Fig 7 1 38 ...
Страница 40: ...7 1 Mechanical Components 7 1 Squeegee Abb 30 Fi 7 3 Abb 30 Fig 7 2 Fig 7 3 Fig 7 2 40 ...
Страница 44: ...7 2 Forward and Reverse Switch The pictures below show the wiring of the switch 44 ...
Страница 45: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 45 ...
Страница 46: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 46 ...
Страница 76: ...11 Adjustment of Disk Brake 76 ...
Страница 80: ...12 2 Notes 80 ...