9.3 Drive Control Unit
ATECH / ZAPI
21) POSITION HANDLE
If upon switching on, the handle micro-switch has already been actuated, error is
signalled (only if SAFETY SWITCH is programmed to HANDLE). Possible causes:
a) Handle micro-switch stuck
b) Incorrect operation
22) INVERSION
22) INVERSION
If upon switching on, the emergency reverse (dead man) button is depressed, an alarm
is output. Possible causes:
a) Micro-switch for emergency reverse stuck
b) Incorrect operation
c) Incorrect wiring or programming
c) Incorrect wiring or programming
23) FORW - BACK
An error is displayed if two directions are simultaneously active.
Possible causes:
a) Wiring defective.
b) Direction micro-switch stuck. If none of the causes applies, replace logic!
24) BATTERY
Battery discharged i.e. battery voltage has fallen below 60% of nominal voltage. An
alarm is output. The system switches off but can be re-started. Maximum current then
will be reduced to 50% of programmed maximum current value.
71
Содержание ERIDE 30
Страница 19: ...3 Technical Data 19 ...
Страница 22: ...4 2 System Maintenance I The following maintenance work must be performed by an authorized Service Center 22 ...
Страница 23: ...4 3 System Maintenance II The following maintenance work must be performed by an authorized Service Center 23 ...
Страница 38: ...7 Mechanical Components 7 1 Squeegee Fig 7 1 38 ...
Страница 40: ...7 1 Mechanical Components 7 1 Squeegee Abb 30 Fi 7 3 Abb 30 Fig 7 2 Fig 7 3 Fig 7 2 40 ...
Страница 44: ...7 2 Forward and Reverse Switch The pictures below show the wiring of the switch 44 ...
Страница 45: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 45 ...
Страница 46: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 46 ...
Страница 76: ...11 Adjustment of Disk Brake 76 ...
Страница 80: ...12 2 Notes 80 ...