5.
Cleaning Programs (FPV)
The cleaning programs define the behavior of the water supply to the brushes, the
brush motors in respect of the position of the drive direction switch, the drive
potentiometer (forwards, neutral, reverse) and the squeegee.
The drive direction switch S07 and drive potentiometer switch S08 provide a 24 V
signal for forward drive at input A01.X10:4 and for reversing at input A01.X10:5.
If no voltage signal is applied, the cleaning units are not activated.
The reaction of the cleaning functions is described in Table 5.1.
To select a cleaning program, access the programming level as described in Chapter
2.2.4. The cleaning programs available are listed in Table 5.2.
T
h
B tt
3 f
i
3
d
Th
di
t
To save any program changes, press Button 3 for min. 3 seconds. Then disconnect
the diagnostics connector from A1.
25
Содержание ERIDE 30
Страница 19: ...3 Technical Data 19 ...
Страница 22: ...4 2 System Maintenance I The following maintenance work must be performed by an authorized Service Center 22 ...
Страница 23: ...4 3 System Maintenance II The following maintenance work must be performed by an authorized Service Center 23 ...
Страница 38: ...7 Mechanical Components 7 1 Squeegee Fig 7 1 38 ...
Страница 40: ...7 1 Mechanical Components 7 1 Squeegee Abb 30 Fi 7 3 Abb 30 Fig 7 2 Fig 7 3 Fig 7 2 40 ...
Страница 44: ...7 2 Forward and Reverse Switch The pictures below show the wiring of the switch 44 ...
Страница 45: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 45 ...
Страница 46: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 46 ...
Страница 76: ...11 Adjustment of Disk Brake 76 ...
Страница 80: ...12 2 Notes 80 ...