9.3 Drive Control Unit
ATECH / ZAPI
•9) VACC NOT OK
•Test in rest state;
•Test in rest state;
•Alarm is displayed if, referred to the saved minimum value, potentiometer voltage is
higher than 1V.
•Possible causes:
•
a) Wire broken at potentiometer or inductive sensor
•
a) Wire broken at potentiometer or inductive sensor.
•
b) Potentiometer or the inductive sensor is defective.
•10) I=0 EVER
•Test during ride;
•If current does not exceed a determined minimum value during ride, an error message
appears and the system switches off.
•
Possible causes:
Possible causes:
•
a)Resistance of motor is excessive since motor is defective
•
or contact of carbon brushes is not okay
•
b)The current sensor is defective (replace controller)
60