3-12
Chapter 3 Mchine setting
Machine Setup MENU table
Function name
Set value
Default
Meaning
AUTO Power-off (
NONE/
10 ~ 600min
30min
When no operation has been performed for the
set time, the power supply is automatically turned
“OFF”.
Feeding Unit (
ON/ OFF
ON
You can set the operation method when the ON/
OFF button on the take-up unit is pressed.
Take-up Unit (
ON/ OFF
ON
You can set the operation method when the ON/
OFF button for the take-up device is pressed.
Media Remain (
ON/ OFF
OFF
You can control the remaining amount of media.
TIME (
+4h ~ -20h
Time difference is corrected.
UNIT/ TEMP. (
°C (Centigrade)/°F (Fahrenheit) °C
A unit for displaying temperature is set.
UNIT/ Length (
mm / inch
mm
A unit for displaying length and area is set.
Key Buzzer (
OFF / ON
ON
A buzzer sound when keys are pressed is set.
Media Detect (
AUTO/MANUAL
AUTO
Set the media detection method.
CONFIRM. FEED (
ON / OFF
ON
Set whether media feeding is performed for
checking the result of the test printing etc. or not.
Network &
Mail
Network
(
Set the network.
Check IP
Address
The IP address currently used by this machine is displayed.
Check MAC
Address
The IP address currently used by this machine is displayed.
DHCP
ON / OFF
When it is ON, the IP address given by the DHCP
server is used.
AutoIP
ON / OFF
When it is ON, the IP address is determined by
the AutoIP protocol. However, DHCP is ON,
DHCP has priority.
IP Address
*1
Set the IP address used by this machine.
Def.Gateway
*1
Set the default gateway used by this machine.
DNS
Address
*1
Set the DNS server address used by this machine.
SubNet Mask
*1
Set the digit number of the subnet mask used by this machine.
Event Mail
(
Mail
Deliverry
ON / OFF
OFF
Set whether you send/ do not send the e-mail
when the set event occurs.
Select
Event
Print Start
ON / OFF
OFF
Set whether you send/ do not send the e-mail at
the start of printing.
Print End
ON / OFF
OFF
Set whether you send/ do not send the e-mail at
the end of printing.
Error Event
ON / OFF
OFF
Set whether you send/ do not send the e-mail
when an error occurs.
Warning Event
ON / OFF
OFF
Set whether you send/ do not send the e-mail
when a warning occurs.
Other Event
ON / OFF
OFF
Set whether you send/ do not send the e-mail
when an event other than the above occurs.
Mail
Address
Set the e-mail address to which
you send the event mail.
Alphanumeric characters and symbols (within 96 characters)
Message
Subject
Set the characters to write in the
subject of the event mail.
Alphanumeric characters and symbols (within 8 characters)
Server
Setup
SMTP Address
Set the SMTP server.
SMTP PORT No.
Set the SMTP port number.
SENDER ADDRESS
Set the e-mail address to be used as the sender mail
address.
Auth.
POP before
SMTP
Set the SMTP server authentication method (SMTP
authentication).
SMTP Auth
OFF
USER NAME
*2
Set the user name used for the authentication.
PASS WORD *2
Set the password used for the authentication.
POP3 ADDRESS
*3
Set the POP server.
APOP *3
Set ON/ OFF of APOP.
Содержание SWJ-320EA
Страница 1: ...MIMAKI ENGINEERING CO LTD https mimaki com D203278 13 Original instructions ...
Страница 72: ...3 24 ...
Страница 116: ...KM FW 1 5 MIMAKI ENGINEERING CO LTD 2018 ...