4-10
Chapter 4 Maintenance
4
Open the right side maintenance cover.
(1)
Rotate the screws under the right side
maintenance cover (for two positions) to the
left and remove them.
(2)
Hold the bottom of the right side
maintenance cover and pull it to the front.
(3)
While pulling the right side maintenance
cover downward, remove it.
• If the right side maintenance cover is hard to
remove, use the supplied screwdriver.
5
Clean the wiper and the bracket, and press
the
key.
(1)
Open the right maintenance cover then pull
out it by holding projections at both ends of
the wiper.
(2)
Clean with a clean stick including the
cleaning solution (SPC-0369: Cleaning
solution).
•
Wipe off so
that maintenance washing liquid
for maintenance will not remain.
(3)
Insert it in the original position by holding the
projections at both ends of the wiper.
6
Clean the cap rubber and cap rubber cover
and press the
key.
• Wipe off the ink sticking to the cap rubber and cap
rubber cover with a clean stick dipped in cleaning
solution for maintenance. Wipe off so that
cleaning solution for maintenance will not remain.
• At this time, the discharge passage is cleaned
automatically.
7
Fill up the cap with cleaning solution for
maintenance, using a dropper.
• Fill the cap with the cleaning solution just before
the solution overflows from the cap.
8
Close the right maintenance cover,
and press the
key.
• The nozzles are washed.
• When the nozzles have been completely washed,
the head moves onto the platen.
9
Suction the cleaning solution into a
syringe and squirt about three syringes
worth of solution into each cap.
Right side
maintenance cover
Screw
Projection
• Until washing liquid is filled, [Fill the liquid.] is
displayed on the screen.
Cap rubber