5-12
Chapter 5 Troubleshooting
ERROR 187
HDC SLEW RATE [12 ]
Ink discharge control error
• Turn off the power on the machine and turn it
on after a while.
• When displaying again, contact your local dis-
tributor, our sales office, or service center.
ERROR 188
HDC MEMORY [12 ]
ERROR 18a
Main PCB V_CORE
An error occurred in the main power.
ERROR 18b
Main PCB V1R5B
ERROR 18c
Main PCB V12
ERROR 18e
FLS NOT COMP [12 ]
Ink discharge control error
ERROR 18f
OFFSET START [12 ]
ERROR 18f
OFFSET END [12 ]
ERROR 19d
HDC V36 [12 ]
Abnormal ink discharge voltage was detected.
ERROR 201
COMMAND
Abnormal communication between PC and
printer
• Check the USB cable connection. Use a USB
cable conforming to the standard.
ERROR 202
PARAMETER
ERROR 203
Ment Command
ERROR 206
PRINTING MODE
• Check the USB cable connection. Use a USB
cable conforming to the standard.
• Check output conditions.
ERROR 304
USB INIT ERR
USB device error.
• Turn off the power on the machine and turn it
on after a while.
• When displaying again, contact your local dis-
tributor, our sales office, or service center.
ERROR 305
USB TIME OUT
ERROR 306
USB GET DESC
ERROR 401
MOTOR X
An excessive load was applied to the X motor.
ERROR 402
MOTOR Y
An excessive load was applied to the Y motor.
ERROR 403
X CURRENT
An error due to an excessive current of the X
motor was detected.
ERROR 404
Y CURRENT
An error due to an excessive current of the Y
motor was detected.
ERROR 41b
** NO MEDIA **
With no media loaded properly, the clamp
moved down.
• Load media so that the media comes within
the range of the media sensor.
ERROR 423
TAKE-UP TENSION-BAR
The media set check detected abnormality of
the take-up tension bar at the start of printing.
• Check the media set condition, and remove
any problem.
ERROR 424
FEEDING TENSION-BAR
The media set check detected abnormality of
the feeding tension bar at the start of printing.
Message
Cause
Solution
Содержание SWJ-320EA