Connection should be made via a switched socket. This will
make it easier for service technicians should the appliance
need to be repaired.
The electrical socket must be easily accessible after
installation.
If the plug has been removed or the connection cable is not
supplied with a plug, the steam combi oven must be
connected to the mains supply by a suitably qualified
electrician.
If the switch is not accessible after installation, or if the
appliance is to be hard-wired, an additional means of
disconnection must be provided for all poles. When switched
off, there must be an all-pole contact gap of 3 mm in the
switch (including switch, fuses and relays).
The
voltage and rated load
are given on the
data plate
.
Please ensure these match the household mains supply.
Miele cannot be held liable for any direct or indirect
damage as a result of incorrect installation or electrical
connection.
Miele cannot be held responsible for damage or injury as
a result of a missing or disconnected earthing system
(e.g. electric shock).
It must be ensured that contact cannot be made with any
live electrical components after installation.
Replacing the mains connection cable
A damaged cable must be replaced with a special
connection cable of type H 05 VV-F (PVC insulated), available
from Miele.
It must be replaced by the manufacturer, an authorised
customer service technician or a suitably qualified electrician.
Electrical connection
179