Total power output
See data plate.
Connection and fuse rating
This appliance is supplied for connection to an AC 230 V,
single phase 50 Hz supply, tripping characteristic type B or
C, fuse rating 16 A.
Residual current device
For extra safety, it is advisable to install a residual current
device (RCD), with a trip current of 30 mA.
Disconnecting from the mains
If the appliance's electric circuit is disconnected from the
mains supply, conduct the allocation as follows, depending
on the installation:
–
Safety fuses
Completely remove fuse plugs;
or
–
Screw-out fuse
Press the test button (red) until the middle button (black)
pops out;
or
–
Built-in circuit breaker
(at least type B or C):
Switch the lever from 1 (on) to 0 (off);
or
–
Residual current device
Switch the main switch from 1 (on) to 0 (off) or press the
test button.
After disconnection, ensure the appliance cannot be
switched back on inadvertently.
Electrical connection
180