All parts used for connecting the appliance to the mains
water supply must comply with current national and local
safety regulations in the country in which the appliance is
being installed.
The appliance can only be connected to a
cold water
connection
.
This appliance is constructed to comply with German water
regulations (DVGW), and may be connected to a suitable
supply without an extra non-return valve if national regulations
permit.
The water pressure needs to be at least 100 kPa (1 bar), but
must not exceed 600 kPa (6 bar). If the water pressure does
exceed 600 kPa (6 bar), a pressure-reducing valve must be
fitted.
Connection to the water supply should be carried out by a
qualified plumber and should incorporate a tap with a 3/4"
thread.
The tap should be fitted by a qualified plumber.
The stainless steel water inlet hose supplied with the
appliance must not be shortened.
If necessary, an inlet hose measuring 1500 mm (1.5 m) is
available, but must not be shortened either.
Old or used hoses must not be connected to this
appliance.
Only original Miele hoses should be used.
The total hose length must not exceed 7500 mm (7.5 m).
Before connecting the appliance and each time work is
carried out on the water inlet system, the water inlet hose
should be rinsed through in order to eliminate any deposits.
Plumbing in the appliance