Error Code
Description
Problem
Possible Cause/Action
E50/E55
inverter board
speed signal lost
or blocked.
inverter
board speed
signal lost
•
change the inverter.
E50/E56
frequency board
motor
overtemperature.
motor
overtemperature
E50/E57
frequency board
radiator
overtemperature.
frequency board
radiator
overtemperature
•
change the inverter
E50/E58
frequency board
motor overload
or motor open
phase.
frequency
board motor
overload or
motor open
phase.
•
1. check motor wire
2. change inverter
3. check whether the system is blocked.
E50/E5B
inverter board
reset fault.
•
change the inverter.
E50/E5C
inverter board
overvoltage.
inverter board
overvoltage.
•
check power system
E50/E5D
inverter board
undervoltage
inverter board
undervoltage.
•
check power system
E50/E5E
inverter board
ultra high voltage.
inverter board
read write flash
fault.
inverter board
read write flash
fault.
•
change the inverter.
–
6
1
–
•
change the inverter.
inverter board
reset fault.
inverter board
ultra high
voltage.
•
check power system
E50/E5F
NOTE: It’s important to note error codes should only be used to help identify those components which
require testing. Never replace a part based solely on an error code. The control can generate a false error
if the right conditions exist . Use the code only as a reference and always check the component before
replacing.
E50/E5A Inverter
Communication
Failed.
Can not check
the
communication
Check the inverter communication wire
Chek the inverter
Check the main contorl
•
•
•
Содержание MFH180-G1302DS F01E-EU