4
2
–
To remove the water valve:
Disconnect the 4 connectors from the cold water
(C) solenoid.
Disconnect the 2 connectors from the hot water
(H) solenoid.
Disconnect the valve outlet hose:
Note:
The valve outlet hose is dif
fi
cult to remove.
a. Squeeze the clamp and slide it back.
b. Carefully break the hose loose by inserting a
small
fl
at-blade screwdriver under the hose
to break the seal.
c. Remove the hose.
1.
2.
3.
Outlet Hose
Move the valve horizontally to the right.
5.
Remove the two
hex-head screws that holds
the valve to the cabinet.
4.
Pump
The pump consists of a 120 VAC, 60-Hz motor,
impeller, impeller housing, and a removable strainer
that helps prevent foreign objects from entering the
pump impeller and drain outlet.
The pump runs whenever the washer is in the
spin function of a cycle.
The pump runs if the water level control
over
fl
ow switch is closed and the washer is
plugged in. (Over
fl
ow protection)
The pump is capable of eliminating 17 gallons
(64 liters) per minute.
Recommended minimum standpipe diameter is
1
1
/
4
inches.
Standpipe maximum height is 96 inches,
measured from the
fl
oor at the washer location.
The pump motor has an approximate resistance
value of 10.6
Ω
.
Speci
fi
c failures as sociated with the pump can
initiate error codes E
20
. (See
Service Test Mode.
)
•
•
•
•
•
•
(Continued Next Page)
Cold Water
Hot Water
Содержание MFH180-G1302DS F01E-EU
Страница 28: ... 28 Dispenser Drawer Tub Drive Pulley Belt Motor Component Locator Views Con t ...
Страница 29: ... 29 Inverter Board Control and Inverter Board Connections Control Board ...
Страница 59: ... 62 Washer MFH210 G1301DS F01E US MFH210 G1301DSF01E US13 MFH210 G1301DSF01E S US13 MLH52S7AWW MLH52S7AGS ...