4
1
–
Overf ow Water Level
Operation of the water level control can be checked
by using service test mode t06. (See
Service Test
Mode
.)
Speci
fi
c failures associated with the water level
control can initiate error codes E23 an
d E65.
(See
Service Test Mode
.)
The over
fl
ow water level is approximately
5.5
inches
above the door opening. Over
fl
ow protection will
occur at this water level.
(Continued Next Page)
Pressure Tube
Tab
To remove the water level control:
Remove the top panel. (See
Top Panel
.)
Press down the single tab, then disconnect each
of the
1
wire harness.
Remove the pressure tube.
Note:
The pressure tube is dif
fi
cult to remove.
a. Squeeze the clamp and slide it back.
b. Carefully break the hose loose by inserting a
small
fl
at-blade screwdriver under the hose
to break the seal.
c. Remove the hose.
Pull the bottom of the water level control outward,
rotate it
1
/
4
-turn clockwise to clear the suspension
spring.
1.
2.
3.
Water Valve
The water valve assembly consists of
2
valve body
and
3
solenoid coils. The water valve has a
fl
ow
rate of 2.1 gallons (8 liters) per minute. It is inserted
and retained in a cutout in the rear of the cabinet
and held in place by a single 6-mm hex-head screw.
It is only available as a complete assembly.
Each solenoid coil has an approximate resistance
value of 1.1K
Ω
.
Speci
fi
c failures associated with the water valve
can initiate error codes E
10
. (See
Service Test Mode.
)