39
(2T0043800036)
8.3.4 Dehumidifying mode
8.3.4.1 Indoor fan speed is low.
8.3.4.2 Four-way valve is closed, the compressor and outdoor fan will operate the same
as in cooling mode.
8.3.5 Auto Mode
MFE-60ARN1-RB4W (2T0043800036):
8.3.5.1. Under auto mode, the indoor fan is set to be auto.
8.3.5.2 When entering auto mode, the heating, fan only or cooling operation will be
automatically chosen according to the room temperature T1 and the set temperature Ts.
Condition
Mode
T1-Ts>1°C
Cooling
-1°C
≤
T1-Ts
≤
1°C
Fan
T1-Ts<-1°C
Heating(fan for cooling only type)
Indoor fan will run at auto fan of the relevant mode.
The louver operates same as in relevant mode.
If the machine switches mode between heating and cooling, the compressor will keep
stopping for 15 minutes and then choose mode according to T1-Ts.
If the setting temperature is modified, the machine will choose running function again.
The others models:
8.3.5.1. Under auto mode, the indoor fan is set to be auto.
8.3.5.2 When entering auto mode, the heating, fan only or cooling operation will be
automatically chosen according to the room temperature T1 and the set temperature Ts.
Condition
Mode
3°C
≤
T1-Ts
Cooling
-3°C
≤
T1-Ts
≤
3°C
Fan
T1-Ts<-3°C
Heating(fan for cooling only type)
8.3.5.3. After one mode is chosen, the operation mode will be re-chosen according to the
T1 and Ts.
Condition
Mode
3°C
≤
T1-Ts
Cooling
-3°C
≤
T1-Ts
≤
3°C
Former mode
T1-Ts<-3°C
Heating(fan for cooling only type)
8.3.6 Fan Only mode
MFE-60ARN1-RB4W (2T0043800036):
8.3.6.1 Temperature setting function is disabled, and no setting temperature is displayed.
8.3.6.2 Under this mode, four-way valve, compressor and outdoor fan are shut down.
8.3.6.3 High/Low/Auto fan can be switched over through manual control. Auto fan will be
Содержание MFE-60AMN1-RB4W
Страница 6: ...3 2 Dimension 2 1 Indoor Unit Dimension Mode W mm D mm H mm 55K 600 358 1900...
Страница 9: ...6 4 Wiring diagram 4 1MFE 60AMN1 RB4W Indoor Unit Outdoor Unit...
Страница 10: ...7 4 2MFE 60ARN1 RB4W 2T0043800026 Indoor Unit Outdoor Unit...
Страница 11: ...8 4 3MFE 60ARN1 RB4W 2T0043800036 Indoor Unit Outdoor Unit...
Страница 49: ...46 9 3 8 Overload of current...
Страница 50: ...47 9 3 9 Indoor outdoor unit communication error...