5. Installation details
5.1 Installation place
5.1.1 Indoor Unit
a.Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
b.There should not be any heat source or steam near the unit.
c.There should not be any obstacles blocking the air circulation.
d.A place where air circulation in the room is good.
e.A place where drainage can be easily done.
f.Do not install the unit near the door way.
g.There should not be any direct sunlight. Otherwise, the sun will fade the plastic
cabinet and affect its appearance. If unavoidable, sunlight prevention should be taken into
consideration.
5.1.1.1 Please stand the unit in hard and flat ground;
Please reserve space for installation and maintenance.
5.1.2 Outdoor Unit
The outdoor unit should be put in a position that guarantees the minimum space for
sufficient air circulation and to allow maintenance work and the connections of electrical
and refrigerant circuit lines. It may be installed on a floor or flat roof or wall-mounted,
provided its weight is properly supported and there is no transmission of vibration to the
adjacent rooms.
5.1.2.1 Before installing the outdoor unit, you should:
a).If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat
radiation from the condenser is not obstructed.
b).Select a place that is easy to connect indoor unit's pipe and electric wires.
c).Avoid a place where combustible gas may leak or stay.
d).Keep it in mind that water may drain out of the outdoor unit while in "Heat" mode.
e).Ensure the space around the back and sides and the front of the unit.
f).Take the air conditioner weight into account and select a place where noise and
vibration are minimum.
5.1.2.2 If the outdoor unit is to be installed on a roof or where no constructions are around,
you should avoid hard wind blows directly to the air outlet, because
Содержание MFE-60AMN1-RB4W
Страница 6: ...3 2 Dimension 2 1 Indoor Unit Dimension Mode W mm D mm H mm 55K 600 358 1900...
Страница 9: ...6 4 Wiring diagram 4 1MFE 60AMN1 RB4W Indoor Unit Outdoor Unit...
Страница 10: ...7 4 2MFE 60ARN1 RB4W 2T0043800026 Indoor Unit Outdoor Unit...
Страница 11: ...8 4 3MFE 60ARN1 RB4W 2T0043800036 Indoor Unit Outdoor Unit...
Страница 49: ...46 9 3 8 Overload of current...
Страница 50: ...47 9 3 9 Indoor outdoor unit communication error...