Page 72
PROFINET, Documentation
optoNCDT 1900 / Profinet
Parameter
Data type
Info
Block Header
Block Type
UINT16
0x0020
Block Length
UINT16
0x0038
Block Version High
UINT8
0x01
Block Version Low
UINT8
0x00
I&M0
Manufacturer ID
UINT16
0x0426 (MICRO-EPSILON Messtechnik GmbH)
Order ID
UINT8(20)
„4120xxx.001“
Serial Number
UINT8(16)
Hardware-Revision
UINT16
z. B. 0x0003
Software-Revision Prefix
UINT8
Character describing the software of the (sub) module.
Allowed values: ‘V’, ‘R’, ‘P’, ‘U’ and ‘T’
Sofware-Revision X
UINT8
Function Enhancement (Major Version Number)
Software-Revision Y
UINT8
Bug Fix (Minor Version Number)
Software-Revision Z
UINT8
Internal Change (Build Version Number)
Revision Counter
UINT16
Starting from 0, shall increment on each parameter change
Profile ID
UINT16
0
Profile specific type
UINT16
5
IM Version
UINT16
The I&M version. (Default value 0x0101)
IM Supported
UINT16
Bit list describing the I&M variants supported by the (sub)
module:
0x02 -> I&M1 Supported
0x04 -> I&M2 Supported
0x08 -> I&M3 Supported
0x10 -> I&M4 Supported
0x20 -> I&M5 Supported
Fig. 35 Struktur I&M0-Record, Index: 0xAFF0, Zugriff: Read-Only