Page 80
PROFINET, Documentation
optoNCDT 1900 / Profinet
8.6.3.8
Load and Apply Presets
Name
Parameter ID
Data type
Description
Access
Mode
55000
UINT8
Returns the currently used preset mode (signal quality); with
<Parameter>
the preset mode (signal quality) to be used is set.
0 - None
1 - Static
2 - Balanced
3 - Dynamic
4 - No averaging
rw
List
55001
STRING(230) Lists all existing manufacturer-specific programs.
ro
Read
55002
STRING(32)
Loads and executes a preset
< Name>
for use in the sensor.
wo
8.6.3.9
Load, Save and Apply Setups
Name
Parameter ID
Data type
Description
Access
Current
55500
STRING(32)
Returns the name of the currently used preset or setup.
ro
Read
55501
STRING(32)
Loads and executes a setup
<Name>
for use in the sensor.
wo
Store
55502
STRING(32)
Saves the current user-specific settings to a Setup
<name>
or a new
Setup
<Name>
is created in non-volatile memory.
wo
Delete
55503
STRING(32)
Deletes the associated setup
<name>
wo
Initial
55504
STRING(32)
Returns the name of the setup intended for the next start of the sensor.
With
<name>
a setup is determined, which will be used at the next start
of the sensor.
Presets cannot be indicated.
rw
List
55505
STRING(230) Returns the names of all saved setups.
ro