Page 97
PROFINET, Documentation
optoNCDT 1900 / Profinet
The examples below show how to turn off the laser light source on the sensor.
WRREC_DB
REQ :=
ID :=
INDEX :=
LEN :=
DONE =>
BUSY =>
ERROR =>
STATUS =>
RECORD :=
Status/Result Output
Enable-Flag
HW-ID
Objekt Index
8Byte + Data Length
15
0x2530
273
1
0
0 0 0x01 0 0x07
Write-Header (8 Byte)
Reserved Reserved
Subindex
Reserved
Reserved
Data length
(UINT32-LE)
ParamID 50500
Value 0 = 0x00000000
0 0 0
0x44 0xC5 0x00 0x00 0x00 0x00 0x00
PARAMID: 50500 VALUE: 0
Fig. 52 SPS write command with 8 Byte prefix to turn off the laser light source on the sensor
RDREC_DB
REQ :=
ID :=
INDEX :=
LEN :=
DONE =>
BUSY =>
ERROR =>
STATUS =>
RECORD :=
Status/Result Output
Enable-Flag
HW-ID
Objekt Index
Data Length
4
0x2530
273
1
0
Value
0
= 0x00000000
0x00 0x00 0x00 0x00
VALUE: 0
Fig. 53
SPS read command to turn off the laser light source on the sensor