Page 64
Setting Sensor Parameters
optoNCDT 1900 / Profinet
7.7.5
Reset Sensor
Reset sensor
Device settings
Button
Clears the settings for baud rate, language, unit, key lock and echo mode
and loads the default parameters.
Measurement setting
Button
Clears the settings for measuring rate, trigger, evaluation range, peak se-
lection, error handling, averaging, zeroing/mastering, data reduction and
setups. Loads the 1st preset.
Reset all
Button
Clears the sensor settings, measurement settings, access authorization,
password and setups. Loads the 1st preset.
Reboot sensor
Button
Reboots the sensor with the settings from the favorite setup,
7.7.6
Bootmode
-
Industrial Ethernet
: The sensor starts or changes to the regular PROFINET operation.
Save your settings when you have finished programming, see Chap.
The sensor must have an IP address so that the web interface and the PLC can access the sensor
in
parallel via Ethernet (TCP/IP and
UDP protocols)
.
Fields with gray background require a selection.
Value
Fields with dark border require entry of a value