Page 53
Instruction Manual Software
thicknessCONTROL MTS 8201.LLT / 4350006.71
Axis section
:
- Distance travelled: Distance travelled by the measuring system in the selected period.
- Distance since last maintenance: Distance travelled by the measuring system in the
selected period since the last maintenance.
- Last service: Time of the last service performance.
- Warning, Alarm: Indicates if maintenance is required. The warning occurs after half a
year and the alarm after one year. The fact that maintenance is required is also indicated
in the system overview. The necessary maintenance steps for the warning or alarm is
explained in more detail in the chapter “Maintenance”.
After maintenance or service has been performed, the interval must be reset by pressing
the Reset button.
Under the
Axis
section, the currently produced length is displayed as in the System
Overview.
With the
Export
button all gap values with the corresponding date and time can be
exported to a file.
5.11.5 Properties
Under the menu item
Extras > Properties
a new view opens.
In this view the user can set the scaling factor for the analog output (deviation from the
setpoint of the thickness Track1, Track3 and Track5). This is specified in mm per volt.
In the figure below, this value is set to 0.1 mm per volt.
Fig. 63 Properties
Содержание 4350006.71
Страница 1: ...thicknessCONTROL MTS 8201 LLT O Frame Non contact thickness measurement Operating Instructions ...
Страница 12: ...Page 12 Laser Safety thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Страница 62: ...Page 62 Instruction Manual Software thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Страница 64: ...Page 64 Pneumatic Plan thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Страница 70: ...Page 70 Declaration of Incorporation thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Страница 95: ...Operating Instructions scanCONTROL 29xx ...
Страница 99: ...scanCONTROL 29xx Appendix A 1 Accessories 60 A 1 1 Recommended Accessories 60 A 1 2 Optional Accessories 61 ...
Страница 100: ......
Страница 135: ...Page 41 Operation of the Sensor with a PC scanCONTROL 29xx Fig 24 Predefined measuring fields ...
Страница 193: ......
Страница 194: ......
Страница 229: ......