Description
Ref. No.
Upstand bracket ...................
29-925-10
Spiral anchor DW15/100 .......
29-921-10
Quick anchor ........................
29-922-70
Quick anchor DW 15
anchor plate .........................
29-922-73
Quick anchor fixture .............
29-922-75
Tie rod DW 15/45 .................
29-900-76
Flange nut 100 .....................
29-900-20
Adjustable spanner ...............
29-926-95
Anchoring – Upstand bracket
Fig. 31.2
Fig. 31.3
Fig. 31.4
Fig. 31.5
Fig. 31.1
Facing can be bolted directly to
the upstand bracket (Fig. 31.1)
or a wall formwork panel can be
placed up against it.
It has an adjustment range of
10 cm.
The height of the upstand form-
work must not be greater than
15 cm.
The maximum distance between
the upstand brackets for MEVA
panels is 240 cm.
Installing the upstand bracket
To install the upstand bracket,
press a spiral anchor DW 15 or
the quick anchor into the fresh
concrete (Fig. 31.2).
When the concrete has set
and the polystyrene core (spi-
ral anchor DW 15) has been
removed, the upstand bracket
can be anchored to the ground
with a tie rod DW 15 and a
flange nut 100 (Fig. 31.3).
The facing or the wall formwork
panel are now placed up against
the upstand bracket (Fig. 31.4).
Minimum 12 cm
Max. 15
Spiral anchor 15/100 / quick anchor
Spiral
Tie rod DW 15
Flange nut 100
Upstand bracket
Upstand formwork
STB-31
Technical Instruction Manual / Status November 2019
STB
Support frame