Anchoring details for STB 300
Figures 23.1 and 23.2 show the
STB 300 being used with hori-
zontal panels.
In this case the installation
dimension of the anchor or the
anchor loop is 15 cm (front face
of the formwork panel to the exit
point of the tie rod axis).
Figures 23.3 and 23.4 show the
STB 300 used with vertical panels
and an alignment rail between
the formwork and the support
frame, e.g. for compensation and
corner solutions. We recommend
using anchor loop 15.
In this case the installation
dimension of the anchor or the
anchor loop is 25 cm (front face
of the formwork panel to the exit
point of the tie rod axis).
When using the STB cross brace,
use single tie rods DW 15 in the
corner area.
This guideline refers to the use of
a formwork panel with a frame
depth of 12 cm.
Fig. 23.2
Fig. 23.4
25
25
25
15
25
15
Fig. 23.1
25
25
Fig. 23.3
Description
Ref. No.
Anchor loop 15 .....................
29-001-20
Anchor loop 20 .....................
29-001-25
Coupling nut
15 (WAF 30) .........................
29-900-55
20 (WAF 36) .........................
29-900-50
Tie rod DW 15/90 .................
29-900-80
Tie rod DW 20/120 ...............
29-900-97
Flange nut 100 .....................
29-900-20
Articulated flange nut 15/120
29-900-10
Articulated flange nut 20/140
29-900-05
M cross stiffener 44 ..............
29-401-02
Formwork panel
shown: frame
depth 12 cm
Formwork panel
shown: frame
depth 12 cm
Support frame
Alignment rail
Support frame
DW 15
DW 15
DW 15
DW 15
STB-23
Technical Instruction Manual / Status November 2019
STB
Support frame