FCM9002 USER MANUAL
76-02-095 Rev.B
Page 116 of 145
4.6 Flow ( Services )
In the FCM9002, Flows define how user traffic traverses the device. The Flow
defines the Tag values that will be pushed as well as the SLA parameters.
The FCM9002 supports a maximum of 16 flows, however the actual number
available in any application is dependant upon the complexity of the C-Tag range
allocations.
The top level flow menu is as below:
Metrodata FCM9002 "FCM9002" Alarms: Major
FLOWS
List Flows
<display>
View/EditRemove <menu>
Add Flow
<menu>
First CAPITAL - select item
<escape> - exit menu
4.6.1 List Flows
This display item lists all the currently configured flows and displays the key
parameters for the flows:
Metrodata FCM9002 "FCM9002_Right" Alarms: Major
FLOWS
-----
# Name St S-Tag Port C-VLANs CIR EIR
---------------------------------------------------------------------
1 Gold Service Up 1 LAN2 1-4095 10M 10M
2 Silver Service Up 2 SFP 1-4095 10M 10M
<Escape> - exit, other key – refresh