![Metro Therm SHK 200S Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/metro-therm/shk-200s/shk-200s_installation-and-operating-manual_1779421052.webp)
52
SHK 200S
SHK 200S-6
Chapter 9 |
Control
Mark “search installed slaves" and press the OK
button to automatically find connected slaves for the
master heat pump.
Enter how your system is docked regarding pipes, for
example to pool heating, hot water heating and heat-
ing the building.
This menu has a docking memory which means that
the control system remembers how a particular re-
versing valve is docked and automatically enters the
correct docking the next time you use the same re-
versing valve.
Make different system settings for your installation
here, e.g. activate connected slaves and which ac-
cessories are installed.
If a slave is connected to the master installation, set
it here.
There are two ways of activating connected slaves.
You can either mark the alternative in the list or use
the automatic function "search installed slaves".
Set whether the compressor in the heat pump should
work to a particular curve under specific requirements
or if it should work to predefined curves.
You set a curve for a demand (heat, hot water etc.) by
unticking "auto", turning the control knob until a tem-
perature is marked and pressing OK. You can now
set at what temperatures the max. and min. frequen-
cies, respectively will occur.
This menu can consist of several windows (one for
each available demand), use the navigation arrows
in the top left corner to change between the windows.
Menu 5.2 - system settings
Menu 5.2.2 - installed slaves
Menu 5.2.3 - docking
Menu 5.1.23 - compressor curve
NOTE
This menu is only displayed if the controller is connect-
ed to a heat pump with inverter controlled compressor.
search installed slaves
This menu contains several sub-menus, one for each
standard.
Menu 5.1.22 - heat pump testing
NOTE
This menu is intended for testing the controller according
to different standards. Use of this menu for other reasons
may result in your installation not functioning as intended.
CAUTION
The compressor curves can only be edited by qualified
personnel.
Factory setting:
Slave:
Here you select for which heat pump the dock-
ing setting is to be made.
Compressor:
Select if the compressor in the heat
pump is blocked (factory setting), or standard (docked
for example to pool heating, hot water charging and
heating the building).
Marking frame:
Move around the marking frame us
-
ing the control knob. Use the OK button to select what
you want to change and to confirm setting in the op
-
tions box that appears to the right.
Workspace for docking:
The system docking is
drawn here.
Slave (heat pump)
Workspace for docking
Compressor
Marking frame
CAUTION
Changing the factory range will result in incorrect op-
eration of the device.
Содержание SHK 200S
Страница 2: ......
Страница 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Страница 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 76: ...76 SHK 200S SHK 200S 6...
Страница 77: ...77 SHK 200S SHK 200S 6...
Страница 78: ...78 SHK 200S SHK 200S 6...
Страница 79: ......
Страница 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...