![Metro Therm SHK 200S Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/metro-therm/shk-200s/shk-200s_installation-and-operating-manual_1779421028.webp)
28
SHK 200S
SHK 200S-6
7 Start-up and regulation
Preparations
Filling the DHW heater
at SHK 200S / SHK 200S-6
1. Check whether the switch in the controller is in
the position „ ”.
2. Check whether the drain valve has been com-
pletely closed, and whether the temperature lim-
iter has not been activated (FD1).
3.
Compatible METROTHERM air/water heat
pumps have been listed in the Connection Op
-
tions section.
1.
Open the hot water tap in the building to the tank.
2.
Open the valve cutting off cold water. When doing
so, the valve should be completely open.
3.
When water starts to flow out of the hot water tap,
DHW heater is full and the tap can be closed.
1.
Open the vent at the top point of the heating sys
-
tem.
2. Set all the isolation valves in the position allowing
for flow in all circuits.
3.
Open the valve for filling the heating installation
and fill it with the heating medium.
4.
Close the vent when the heating medium flows
out of it continuously (without air bubbles).
5. Control the manometer showing pressure in-
crease. Fill the system until the pressure of 2 bar,
and then close the filling valve.
6. Start the circulation pump of the heating system
every now and then, while opening the vents
placed on the heating circuit.
7.
Open the safety valve until the pressure at the
manometer falls down to about 1 bar of the nor-
mal operating range.
8. If, while venting, the pressure drops down below
1 bar, supplement the heating medium in the cir-
cuit.
1. Connect the hose to the external drain valve of
the system.
2. Then open the drain valve to empty the heating
system.
Filling and venting
Filling and venting the heating system
and SHK 200S / SHK 200S-6
Emptying the heating system
Chapter 7 |
Start-up and regulation
Содержание SHK 200S
Страница 2: ......
Страница 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Страница 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 76: ...76 SHK 200S SHK 200S 6...
Страница 77: ...77 SHK 200S SHK 200S 6...
Страница 78: ...78 SHK 200S SHK 200S 6...
Страница 79: ......
Страница 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...