Menu 1.3 - scheduling
In the menu scheduling indoor climate (heating/cool-
ing/ventilation) is scheduled for each weekday. You
can also schedule a longer period during a selected
period (vacation) in menu 4.7.
In menu 1.3, select heating or cooling, then program
the room temperature increase or decrease for up to
three time intervals throughout the day. More informa
-
tion after selecting "?".
Activated:
Scheduling for the selected period is activat-
ed here. Set times are not affected at deactivation.
System:
Which climate system the schedule is for is
selected here. This alternative is only displayed if more
than one climate system is present.
Day:
Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a par-
ticular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line "all"
is used, all days in the period are set for these times.
Time period:
The start and stop time for the selected
day for scheduling are selected here.
Adjustment:
See relevant sub menu.
Conflict:
If two settings conflict with each other a red
exclamation mark is displayed.
Factory setting:
heating: wył.
cooling: wył.
Menu 1.9 - Advanced
Menu 1.9.1 - curves
This menu is intended for advanced users. This menu
has several sub-menus.
You can select heating or cooling in the curve menu.
The next menu (heating curve/cooling curve) shows
the heating and cooling curves for your house. The
task of the curve is to give an even indoor temper-
ature, regardless of the outdoor temperature, and
thereby energy efficient operation. It is from these
heat curves that the heat pump’s control computer
determines the temperature of the water to the sys-
tem, the supply temperature, and therefore the indoor
temperature. Select the curve and read off how the
supply temperature changes at different outdoor tem-
peratures here. The number to the far right of "sys-
tem" displays which system you have selected the
heating curve/cooling curve for.
The optimum slope depends on the climate condi-
tions in your location, if the house has radiators or un-
der floor heating and how well insulated the house is.
The curve is set when the heating installation is in-
stalled, but may need adjusting later. Normally, the
curve will not need further adjustment. More informa
-
tion after selecting "?".
The figure at the end of the curve indicates the curve
slope. The figure beside the thermometer gives the
curve offset. Use the control knob to set a new value.
Confirm the new setting by pressing the OK button.
Curve 0 is an own curve created in menu 1.9.7.
Factory setting:
Heating curve: 7
CAUTION
When making fine adjustments of the indoor tempera
-
ture, the curve must be offset up or down instead, this
is done in menu 1.1 temperature.
IMPORTANT
Under floor heating systems are normally max flow line
temperature set to between 35 and 45 °C. Must be re
-
stricted with underfloor cooling min. flow line temp. to
prevent condensation. Check the max temperature for
your floor with your installer/floor supplier.
Chapter 9 |
Control
Содержание SHK 200S
Страница 2: ......
Страница 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Страница 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 76: ...76 SHK 200S SHK 200S 6...
Страница 77: ...77 SHK 200S SHK 200S 6...
Страница 78: ...78 SHK 200S SHK 200S 6...
Страница 79: ......
Страница 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...