![Metro Therm SHK 200S Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/metro-therm/shk-200s/shk-200s_installation-and-operating-manual_1779421042.webp)
42
SHK 200S
SHK 200S-6
Menu 1.9.2 - external adjustment
Menu 1.9.3 - min. flow line temp.
Menu 1.9.4 - room sensor settings
Connecting an external contact, for example, a room
thermostat or a timer allows you to temporarily or pe-
riodically raise or lower the room temperature while
heating. When the contact is on, the heating curve
offset is changed by the number of steps selected in
the menu. If a room sensor is installed and activated
the desired room temperature (°C) is set. If there is
more than one climate system the setting can be made
separately for each system. More information after se
-
lecting "?".
Here you can turn on room sensors that regulate the
room temperature.
Here you can set a factor (a numerical value) that de-
termines how much an over or sub normal temperature
(the difference between the desired and actual room
temperature) in the room is to affect the supply tem-
perature to the climate system. A higher value gives
a greater and faster change of the heating curve's set
offset. More information after selecting "
?".
In menu 1.9.3 you select heating or cooling, in the
next menu (min. supply temp.heating/cooling) set the
minimum temperature on the supply temperature to
the climate system. This means that SHK 200S / SHK
200S-6 never calculates a temperature lower than
that set here.
If there is more than one climate system the setting
can be made separately for each system.
ADVICE
Wait 24 hours before making a new setting, so that the
room temperature has time to stabilise.
If it is cold outdoors and the room temperature is too
low, increase the curve slope by one increment.
If it is cold outdoors and the room temperature is too
high, lower the curve slope by one increment.
If it is warm outdoors and the room temperature is too
low, increase the curve offset by one increment.
If it is warm outdoors and the room temperature is too
high, lower the curve offset by one increment.
ADVICE
The value can be increased if you have, for example,
a cellar that you always want to heat, even in summer.
You may also need to increase the value in "stop heat-
ing" menu 4.9.2 "auto mode setting".
Factory setting:
heating
climate system 1: 0
cooling
climate system 1: 0
Factory setting:
heating
climate system 1: 20
cooling
climate system 1: 18
Factory setting:
inactive
IMPORTANT
Too high a set value for "factor system" can (depending
on your climate system) produce an unstable room tem-
perature.
CAUTION
A slow heat-releasing heating system, such as for
example, underfloor heating, may not be suitable for
control using the heat pump's room sensor.
Chapter 9 |
Control
Содержание SHK 200S
Страница 2: ......
Страница 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Страница 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 76: ...76 SHK 200S SHK 200S 6...
Страница 77: ...77 SHK 200S SHK 200S 6...
Страница 78: ...78 SHK 200S SHK 200S 6...
Страница 79: ......
Страница 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...