MI 3394 CE
MultiTester
XA
Technical specifications
129
10.4 Insulation Resistance, Insulation Resistance-S
Insulation resistance (250 V, 500 V, 1000 V)
Range
Resolution
Accuracy
Riso
0.00 M
… 19.99 M
0.01 M
(3 % of r 2 D)
20.0 M
... 199.9 M
0.1 M
10 % of reading
Insulation resistance
–S (250 V, 500 V, 1000 V)
Range
Resolution
Accuracy
Riso-S
0.00 M
… 19.99 M
0.01 M
(3 % of r 2 D)
20.0 M
... 199.9 M
0.1 M
20 % of reading
Insulation resistance, Insulation resistance
–S (50 V, 100 V)
Range
Resolution
Accuracy
Riso
Riso-S
0.00 M
... 19.99 M
0.01 M
(5 % of r 2 D)
20.0 M
... 99.9 M
0.1 M
20 % of reading
Output voltage
Range
Resolution
Accuracy
Um
0 V ... 1200 V
1 V
(3 % of r 2 D)
Operating range (acc. to EN 61557-2) ........ 0.08 M
... 199.9 M
Nominal voltages Un (d.c.).......................... 50 V, 100 V, 250 V, 500 V, 1000V (- 0 %, + 10 %)
Short circuit current .................................... max. 2.0 mA
Test terminals
Function
Connections
Insulation
Mains test socket (LN), ISO(+)
↔ Mains test socket (PE), ISO(-),
TC1
Insulation
– S
Mains test socket (LN), ISO(+) ↔ P/S, TC1
10.5 Substitute Leakage Current, Substitute Leakage
Current - S
Substitute leakage current, Substitute leakage current - S
Range
Resolution
Accuracy
Isub
Isub-S
0.00 mA ... 19.99 mA
10 µA
(5 % of r 3 D)
Operating range (acc. to EN 61557-16) ........... 0.12 mA ... 19.99 mA
Open circuit voltage ......................................... < 50 V a.c.
Current calculated to mains supply voltage (110 V or 230 V) is displayed.
Test terminals:
Function
Connections
Subleakage
Mains test socket (LN), SUB1
↔ Mains test socket (PE), SUB2,
TC1
Subleakage
– S
Mains test socket (LN), SUB1 ↔ P/S, TC1
Содержание MI 3394 CE MultiTesterXA
Страница 1: ...CE MultiTesterXA MI 3394 Instruction manual Ver 3 4 13 Code no 20 752 432...
Страница 80: ...MI 3394 CE MultiTesterXA Single tests 79 Figure 6 19 Examples of Continuity measurement results...
Страница 103: ...MI 3394 CE MultiTesterXA Single tests 102 Figure 6 57 Examples of Power measurement results...
Страница 110: ...MI 3394 CE MultiTesterXA Single tests 109 Save results optional Figure 6 69 Examples of Functional Inspection results...