
10
INSTRUCTION MANUAL
– BALER Z562
Any other figure shown by the counter means that it is faulty. Too low a voltage is
indicat
ed by the counter displaying “
Err1
” alternately with the voltage value, e.g. “
U8.5
”
(it means a voltage of 8.5V). The counter indicates an unacceptably high voltage with an
“
Err2
” message, displayed alternately with the voltage value “
U18.5
” (it means a voltage of 18.5V).
3.5.2 Switching Off The Panel
Switch the counter by pressing the “On/Off” switch (
Włącznik)
. The display shows a
flashing red dot “8.8.8
.
8.” After this message, you can disconnect the counter supply.
To disconnect the plug, loosen the locking bolts (on both sides of the plug) and pull the
plug (not the cord) to disconnect.
3.5.3 Selecting The Bale-Binding Option
The option of baler operation (twine or net-binding) is selected after you have
disconnected the counter, when the display
shows a flashing red dot “8.8.8
.
8.” (Section 3.5 2).
Next, simultaneously press and hold the
“Binding”
and
“On/Off
” keys. The following operational
options are displayed.
•
“
OP-1
” – twine-binding (the “
Binding
” key is disabled). The counter generates an
intermittent acoustic signal, and the
“Binding”
button green indicator lamp is on.
•
“
OP-2
” - net-binding. Press and hold
“Binding”
to start the work of the net-binding unit.
Release the key to stop the work of the unit. The control panel displays “
0
”, or the latest
message.
Press
“Applicator”
or
“Manifold
” to select the option. Hit “
Binding
” to confirm the
selection
.
The control panel enters the selected work mode in the disabled condition (the red
dot is flashing “8.8.8
.
8.”).
3.5.4 Delay-Time Change
Set the
delay time after the counter is switched off, when the red flashing dot “8.8.8
.
8.”
is lit continuously. Simultaneously, press and hold the
“Hydraulic manifold”
and
“On/Off
” keys.
The display shows a message about the delay time for the hydraulic manifold,
e.g. “
t1.30
”,
which means the delay time T1 is 30 seconds. The range of the delay time of the hydraulic
manifold is between 5 and 99 seconds. Press
“Applicator”
(-) or
“Manifold
” (+) to change the
delay time. Press
“Binding
” to confirm. The control panel enters the selected work mode in the
disabled condition (the red dot is flashing “8.8.8
.
8.”).
3.5.5 Resetting
Reset the option of the baler operation after the counter is off, when the display shows
Содержание Z562
Страница 2: ......
Страница 25: ...INSTRUCTION MANUAL BALER Z562 25 Figure 35 Pick up cam adjustment...
Страница 50: ...50 INSTRUCTION MANUAL BALER Z562 NOTES...
Страница 51: ...INSTRUCTION MANUAL BALER Z562 51...