GASOLINE STERNDRIVE INSTALLATION MANUAL
90-860172011
Page 83 of 137
2. Pull out shift linkage as far as it moves. Jaws will open.
72460
a
a -
Shift Linkage
IMPORTANT: As sterndrive is inserted into sterndrive unit, entry of the bell housing
shift cable must be closely checked to make sure cable enters the jaws of shift
linkage assembly in the sterndrive.
3. Place remote control in NEUTRAL position.
NOTE: As bell housing shift cable enters the shift linkage assembly, it pushes the assembly
back into the sterndrive housing, and the jaw closes, securing the cable, as shown in steps
“
A
”, “
B
” and “
C
.”
72467
A
C
B