GASOLINE STERNDRIVE INSTALLATION MANUAL
90-860172011
Page 127 of 137
Refer to gauge manufacturer’s instructions for specific connections.
NOTE:
1
Connect Wires Together with Screw and Hex Nut; Apply Liquid Neoprene to
Connection and Slide Rubber Sleeve over Connection.
NOTE:
2
Power for a Fused Accessory Panel May Be Taken from This Connection. Load
Must Not Exceed 40 Amps. Panel Ground Wire Must Be Connected to Instrument Terminal
That Has an 8-Gauge Black (Ground) Harness Wire Connected to it.
NOTE:
3
Lanyard stop switch lead and neutral safety switch leads must be soldered and
covered with shrink tube for a water proof connection. If an alternate method of connection
is made, verify connection is secure and sealed for a water proof connection.
a -
Audio Warning Alarm
b -
Tachometer
c -
Oil Pressure
d -
Water Temperature
e -
Battery Meter
f -
Ignition Switch
g -
Trim Indicator
h -
Read/Observe NOTE 1 and 2.
i -
Read/Observe NOTE 3.
j -
To Engine Wiring Harness