WARRANTY QUALIFICATION AND SERVICE
The following information verifies proper installation and operation of your Mendota fireplace Insert. All installation and
operating instructions must be carefully followed. This Mendota fireplace Insert must be installed and serviced by a qualified
installer, service agency, or the gas supplier.
7.1
INSTALLER VERIFICATION CHECKLIST
Installer Verification Checklist
Mechanical:
❑
Wood burning fireplace cavity and chimney system are cleaned professionally.
❑
Wood burning chimney interior and chimney top cap are inspected and repaired or replaced if damaged.
❑
Install approved flex vent pipes and vent cap per manual
❑
Flex vent pipe joints must be permanently screw secured and hose clamped tightly
❑
Vent Length conforms to minimum and maximum vertical vent run requirements.
❑
Air intake damper position must be adjusted per vent length, as recommended.
❑
Check for proper clearances to combustibles and vent locations per manual
❑
Install proper size gas lines; check for gas leaks per manual
Plumbing:
❑
Check for correct gas pressure at manifold per manual
❑
Manifold pressure to be 3.5” Inches Water Column
maximum - Nat. Gas (pl
us or minus 1/8”)
❑
Manifold pressure to be 10” In
ches Water Column maximum -
L.P. Gas (plus or minus 1/8”)
❑
Check cycle burners on/off for prompt ignition per lighting instructions
❑
Burners must light immediately.
❑
Flames must travel promptly along entire length of burner.
Setup:
❑
Install logs and adjust flame per manual
❑
Proper pilot flame impingement on burner; air shutter opening: 1/8" Nat. Gas
–
1/4“
-fully open LP.
❑
Check that flame is "stable" and is not "lifting" off burner after draft has been established (approx. five minutes).
❑
Light Pilot
❑
Operate Burner
Homeowner Training:
❑
Train owner on remote control functions
❑
Explain thermostatic functions
❑
Brief and Instruct owner on periodic maintenance of unit
Содержание FV44I Gen 3
Страница 16: ...85 03 01060 D FV44i D cor Gen 3 Page 16 Figure 3 13 Figure 3 12...
Страница 30: ...85 03 01060 D FV44i D cor Gen 3 Page 30 Figure 3 30 Mantel Clearance Reduction Method...
Страница 87: ...85 03 01060 D FV44i D cor Gen 3 Page 87 6 7 2 Convection Air Blower System Parts Figure 6 3 Blower System Parts...
Страница 88: ...85 03 01060 D FV44i D cor Gen 3 Page 88 6 7 3 Burner System Parts Figure 6 4 Burners Systems Parts...
Страница 97: ...Thank you for choosing Mendota...
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...