85-03-01060-D
FV44i Décor Gen 3
Page
58
4.10
NATURAL GAS TO LPG CONVERSION
4.10.1
General Conversion Information
WARNING
This
conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exac tly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the
proper installation of this kit. The installation is not proper and complete un til the operation of the
converted appliance is checked as specified in the owner instructions supplied with t he kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appl iance may result in property damage or personal injury.
Kit # HA-58-00410 for Mendota Model FV44i Decor
This c
onversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all
applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until
the operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.
Caution: The electrical s upply to the fireplace must be turned off prior to performing the conversion. The
gas supply must be shut off prior to disconnecting the electrical power.
4.10.1.1
Orifice sizes requirement
A natural gas to LPG conversion kit #HA-58-00410must be
ordered and installed to convert the FV-44i Decor
Fireplace to burn LPG.
LP Conversion Kit # HA-58-00410 contains the following
parts: One motorized LP pressure regulator #907.012 and
one cap orifice (drill #52).
4.10.1.2
Procedure to Convert This Fireplace to
Burn LPG
This Fireplace Insert arrives from the factory ready to
burn natural gas. If you intend to burn LPG, it is
recommended that you convert this fireplace and its pressure regulator, pilot orifice slider position and burner orifices prior to
placing this fireplace in its fire-place cavity. See diagrams, on this page, and follow these instructions to prepare this fireplace for
conversion to LPG.
1.
Remove the left-side access panel mounted to the left outer skin and lay down gently without disconnecting any wires of
internal components.
2.
Turn off gas supply at the appliance service valve if gas line has been connected to this appliance.
4.10.1.3
Procedure to Convert This Fireplace to Burn LPG
This Fireplace Insert arrives from the factory ready to burn natural gas. If you intend to burn LPG, it is recommended that you
convert this fireplace and its pressure regulator, pilot orifice slider position and burner orifices prior to placing this fireplace in its
fire-place cavity. See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1.
Remove the left-side access panel mounted to the left outer skin and lay down gently without disconnecting any wires of
internal components.
2.
Turn off gas supply at the appliance service valve if gas line has been connected to this appliance.
Figure 4-11 Main Gas Valve
Содержание FV44I Gen 3
Страница 16: ...85 03 01060 D FV44i D cor Gen 3 Page 16 Figure 3 13 Figure 3 12...
Страница 30: ...85 03 01060 D FV44i D cor Gen 3 Page 30 Figure 3 30 Mantel Clearance Reduction Method...
Страница 87: ...85 03 01060 D FV44i D cor Gen 3 Page 87 6 7 2 Convection Air Blower System Parts Figure 6 3 Blower System Parts...
Страница 88: ...85 03 01060 D FV44i D cor Gen 3 Page 88 6 7 3 Burner System Parts Figure 6 4 Burners Systems Parts...
Страница 97: ...Thank you for choosing Mendota...
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...