Page
63
4.12
VENTING
WARNING: Proper installation of the vent system, as re quired in this manual, is vital to the performance of
this Insert. Oversights or failure to conform to all in stallation requirements will void the applicable warranty.
The FV-44i Insert must be vented vertically to the outside and must use one of the approved co-linear
flexible ducting system s or a coaxial flexible ducting system .
This heater must be properly c onnected to a venting system in accordance with the manufacturer's
installation instructions. Operation of this heater when not connected to a prop erly installed and maintained
venting system can result in carbon monoxide (CO) poisoning and possibly death.
If the vent system of this appliance is disconnected for any reason, the vent and air intake systems must be
properly reassembled and resealed before this appliance is put into use.
When existing wood burning chimney size allows, r
un both the 4” exhaust liner and 3” air intake liner to the
vertical vent cap. If
existing wood burning chimney
size is too small to run both 4” and 3” liners, consider c
onverting to a coaxial flex system using a
4” exhaust flex and 6” air intake flex with spring spacers between
the two flex pipes.
NOTE: Mendota recommends that both exhaust and air intake flex liners be run all the way to the vent cap.
Seals between flex liners and unit top and vent cap must be permanent and as air tight as possible. Never use
silicone sealants in pipe joints. Use of sealants at flex pipe joints is not required . Do use both securing
screws and hose clamps at all four flex connection points.
When existing wood burning chimney flue
size is too small to run both 4” and 3” liners
, it is an option to cut the air intake flexible
duct short and run only the 4” vent flexible duct to the vent cap connector. This is generally called “stubbing”. However,
understand that doing so may lead to venting problems. Variations between the air pressure inside the home and atmospheric
air pressures outside the home can cause venting problems and
performance failures.
CAUTION:
Each installation must conform to all local, state
and national code s. Refer to the national fuel gas code and
local zoning and code authorities for details on installation
requirements. The Mendota Ins erts must be vented to the
outside in accordance with the latest edition of the National
Fuel Gas Code. In the absence of local codes, the installation
must conform with National Fuel Gas Code ANSI Z223.1
(NFPA 54), or Canadian Code CAN1 -B149 or most current
edition, also known as NFPA 54. Do not connect this Insert
to a chimney flue serving a separate solid fuel or gas -burning
appliance.
Figure 4-18 Vent System
Содержание FV44I Gen 3
Страница 16: ...85 03 01060 D FV44i D cor Gen 3 Page 16 Figure 3 13 Figure 3 12...
Страница 30: ...85 03 01060 D FV44i D cor Gen 3 Page 30 Figure 3 30 Mantel Clearance Reduction Method...
Страница 87: ...85 03 01060 D FV44i D cor Gen 3 Page 87 6 7 2 Convection Air Blower System Parts Figure 6 3 Blower System Parts...
Страница 88: ...85 03 01060 D FV44i D cor Gen 3 Page 88 6 7 3 Burner System Parts Figure 6 4 Burners Systems Parts...
Страница 97: ...Thank you for choosing Mendota...
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...