3.2
MECHANICAL TECHNICAL REFERENCES
3.2.1
Install Only in Woodburning fireplaces
This Mendota Insert must be installed and serviced by a qualified installer, service agency, or the gas supplier. This Gas Fired
Insert Heater can only be installed inside a Masonry Woodburning Fireplace cavity or inside a Factory Built Zero Clearance
Woodburning Fireplace Cavity. For refacing around an existing Masonry Fireplace or a Factory Built Zero Clearance Woodburning
Fireplace, see
Re-facing a Woodburning Fireplace 3.2.15
.
WARNING: Do not attempt to install this Gas Fired Insert Heater inside any cavities other than a Masonry
Woodburning Fireplace cavity or a Factory -Built Zero Clearance Woodburning Fireplace cavity. Doing so will
lead to a house fire wh ich can lead to property damage, physical injury and possible loss of l ife and will
nullify and void all applicable warranty or claims.
3.2.2
Clearances To Combustibles Materials Inspection Requirement
Before attempting to install this Fireplace Insert in any ZC Woodburning Fireplace or any Masonry Fireplace, It is required that
Clearances to Combustibles be inspected and verified that all clearances requirements are met. For Masonry Fireplaces,
specifically, measure the distance from the top lintel to any combus
tibles that exist above the top lintel. A minimum 12”
clearance is required between the lintel and the closest combustible framing or facing material located above the lintel.
If the measured distance is less than 12”, a fire hazard exists. Do not proceed
with installation of this insert.
Figure 3-1 Factory Built ZC Woodburning Fireplace
Figure 3-2 Masonry Woodburning Fireplace
Содержание FV44I Gen 3
Страница 16: ...85 03 01060 D FV44i D cor Gen 3 Page 16 Figure 3 13 Figure 3 12...
Страница 30: ...85 03 01060 D FV44i D cor Gen 3 Page 30 Figure 3 30 Mantel Clearance Reduction Method...
Страница 87: ...85 03 01060 D FV44i D cor Gen 3 Page 87 6 7 2 Convection Air Blower System Parts Figure 6 3 Blower System Parts...
Страница 88: ...85 03 01060 D FV44i D cor Gen 3 Page 88 6 7 3 Burner System Parts Figure 6 4 Burners Systems Parts...
Страница 97: ...Thank you for choosing Mendota...
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...