85-03-01060-D
FV44i Décor Gen 3
Page
67
4.12.5
Air Intake Damper Adjustment Suggestions
The Insert's vent adapter has a damper plate located on
the 3" air intake tube. The vent damper comes from the
factory set at a 45-degree position. Set the damper
according to the length of venting used.
❑
Below
20’
. leave in the factory position of 45-
degrees.
❑
Above
20’
. close approximately 15-degree for
every
10’
. above
20’
.
❑
Above
50’
. close fully.
Note: Some variations due to offsets in chimney and other factors may require fine tuning the primary damper position.
4.12.6
Attaching Flue Liners to Unit Top Vent Adapter
Once the two flex liners are dropped to the fireplace cavity,
attach the 4” exhaust flex and the 3” air intake flex to the
unit top vent adapter using hose clamps and sheet metal
screws
1.
At the fireplace cavity a
ttach 4” flex vent to 4”
starter
collar on sliding vent adapter.
2.
Secure 4” vent flex to 4” starter collar employing one 4”
hose clamp and a ratchet. Position hose clamp close to
the flashing plate. Compress the flex as much as
possible around the starter collar to obtain a tight joint
between starter stubs and flex inner surface.
3.
Secure the flex liner to the starter collar with sheet
metal screws in two equally spaced radial locations and
above the hose clamp to stop hose clamp from sliding
off.
4.
Repeat procedure for 3” flex.
Figure 4-24 Primary Vent Damper
Figure 4-25 Vent Adapter Flex Connection
Hose Clamp first. Secure w/ Screw above Hose Clamp
Содержание FV44I Gen 3
Страница 16: ...85 03 01060 D FV44i D cor Gen 3 Page 16 Figure 3 13 Figure 3 12...
Страница 30: ...85 03 01060 D FV44i D cor Gen 3 Page 30 Figure 3 30 Mantel Clearance Reduction Method...
Страница 87: ...85 03 01060 D FV44i D cor Gen 3 Page 87 6 7 2 Convection Air Blower System Parts Figure 6 3 Blower System Parts...
Страница 88: ...85 03 01060 D FV44i D cor Gen 3 Page 88 6 7 3 Burner System Parts Figure 6 4 Burners Systems Parts...
Страница 97: ...Thank you for choosing Mendota...
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...