85-03-01060-D
FV44i Décor Gen 3
Page
17
3.2.5
FV44i Insert Ratings Information
This Mendota Insert must be installed in an existing Masonry Wood Burning Fireplace or a Factory Built ZC Wood Burning
Fireplace.
MINIMUM FIREPLACE CAVITY SIZE REQUIREMENT
: 33-1/4
” WIDE X 24
-1/4
” HIGH X 17
-
3/4” DEEP
(depth can be reduced using a
surround with a deep outer edge finish).
ELECTRICAL REQUIREMENTS
: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED
GAS SUPPLY
PRESSURE
: NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
LP GAS CONVERSION KIT
: This insert comes configured for use with Natural Gas. To convert the insert for use with LP Gas, install:
LP GAS CONVERSION KIT HA-58-00410.
GAS INPUT RATES
High Fire
Low Fire
BTUH .......................... NAT. GAS
29,000
18,000
BTUH .......................... L.P. GAS
29,000
22,000
ORIFICE SIZES
…………B
URNER: #38 NAT. [#52 LP];
P.4 EFFICIENCY
..........82.8% NG, 86.7% LP
FLUE VENTING
............CO-LINEAR -
4” DIAMETER EXHAUST & 3” DIAMETER
AIR INLET APPROVED VENTS, 10 Feet Minimum Vent
Length. 55 Feet Maximum Vent Length
WARNING: Low-profile vent caps offered by any brand are not approved for use with Mendota Gas Inserts.
NET WEIGHT
................195 lbs. (Team Lift recommended)
BARRIER SCREEN
: A barrier screen that has been certified for use with this insert must be installed on the Insert when it is in use.
The barrier screen will prevent accidental contact with the glass door face, which could result in a severe burn.
SAFETY
: AGA certified, electronic ignition IPI system activated with thermostatic remote control.
CERTIFIED TO
: ANSI Z21.88-2016
This Mendota Gas Fireplace Insert has been tested and certified by:
Intertek Testing Services, 8431 Murphy Drive, Middleton, WI 53562
Содержание FV44I Gen 3
Страница 16: ...85 03 01060 D FV44i D cor Gen 3 Page 16 Figure 3 13 Figure 3 12...
Страница 30: ...85 03 01060 D FV44i D cor Gen 3 Page 30 Figure 3 30 Mantel Clearance Reduction Method...
Страница 87: ...85 03 01060 D FV44i D cor Gen 3 Page 87 6 7 2 Convection Air Blower System Parts Figure 6 3 Blower System Parts...
Страница 88: ...85 03 01060 D FV44i D cor Gen 3 Page 88 6 7 3 Burner System Parts Figure 6 4 Burners Systems Parts...
Страница 97: ...Thank you for choosing Mendota...
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...