Setting up the AED
Use only Mediana-approved and specified parts, accessories, optional
parts, consumables, and components. Use of unauthorized accessories
may cause the AED to operate improperly and provide false
measurements. Follow all labeling instructions on the defibrillation pads
and the battery.
Always follow your facility
’
s infection control procedures and applicable
regulations when disposing of anything that has been used on patients.
Do not open the pads from packaging previously until the time of
emergency use when pads are used for patient.
The pads should be connected to the AED as preparation for emergency
circumstances.
The AED should not be used or loaded with other equipment. If it is
necessary, the AED should be observed to verify normal operation before
using.
Do not use the expired pads.
Do not reuse the pads. Reuse can lead to potential cross infection,
improper performance of the device, inadequate delivery of therapy,
and/or injury to the patient or operator.
Temperature status
Temperature status displays the following description.
If the self-test is implemented in out-of-range for environmental operation condition,
the status indicator
‘
O
’
will be displayed.
If the self-test is implemented in out-of-range for environmental operation condition
above 5 times, the status indicator
‘
X
’
will be displayed.
When the AED with displaying status indicator
‘
O
’
is turned on in out-of-range for
environmental operation condition.
Note: When the AED with displaying status indicator
‘
X
’
and temperature status is turned
on in specified environmental operation condition, will operate properly.
Note: When the AED is turned on in the inappropriate environmental operation condition,
temperature status will be blink.
Note: If the AED is placed in out-of-range value for environmental operation condition for
long time, it will be longer than usual to recognize the temperature. It is
recommended that AED should be stored in environmental operation condition
described in this manual.
Pads status
Pads status displays the following description.
If the pads are disconnected with the AED, the pads status will be displayed.
For the AED with the pads quality feature, the pads status will be displayed if there is
a problem with the pad connected to the AED. (expiration of the pads, expired pads,
damaged pads or recommended replacement of the pads)
Note: If the pads are normally connected to the pads quality enabled AED but the pad
status indicator is showing, the pads need to be replaced.
Note: If user replaces the pad connected to the pads quality enabled AED and perform a
self test, the pads status indicator will be displayed or not according to the pads
status.
Содержание A16M-DF-0E
Страница 8: ...MEDIANA HEARTON AED A16 Automated External Defibrillator 4...
Страница 16: ...MEDIANA HEARTON AED A16 Automated External Defibrillator 12...
Страница 28: ...MEDIANA HEARTON AED A16 Automated External Defibrillator 24...
Страница 48: ...MEDIANA HEARTON AED A16 Automated External Defibrillator 44...