PELLET STOVES
Chapter 4
USE AND MAINTENANCE MANUAL
page
49
Operation
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
D
G
4.15.
SYNCHRONISING THE REMOTE CONTROL
When the product is started up for the first time you may have to
introduce the new remote control to the stove. To do this, follow these
simple instructions:
connect the cable to the stove and turn on the power switch
check that selector
D
on the emergency panel is in the
REMOTE
when the first writing appears on the emergency panel display
press the sunken button
(G)
using a suitable pointed object
(toothpicks etc. flashing lines will appear on the display of the
panel)
3 flashing lines (---) will appear on the display of the panel.
Press the on/ off button on the remote control to make the
introduction.
The three flashing lines on the display will disappear and the stove will
learn the new communication address for the remote control. The
introduction is also confirmed by 4 acoustic beeps.
4.16.
SAFETY DEVICES
The stove is fitted with the following safety devices:
SMOKE TEMPERATURE SENSOR
This sensor detects the temperature of the smoke, permitting the
stove to start up or shut down when the temperature of the smoke
drops below the preset value.
PELLET TANK TEMPERATURE SENSOR
If the temperature exceeds the safety value set the stove
immediately stops operating. To restart the stove, the sensor must
be reset manually. This can only be done once the stove has
cooled down.
ELECTRICAL SAFETY
The stove is protected against violent current surcharges by a
general fuse situated in the power supply panel at the rear of the
stove. Other fuses to protect the electronic boards are situated on
this panel.
SMOKE BLOWER BREAKAGE
If the blower fan stops, the electronic board promptly suspends
the supply of pellets and the alarm is displayed.
GEARED MOTOR BREAKAGE
If the geared motor stops the stove continues to operate until the
minimum cooling level is reached.
BRIEF POWER FAILURE
In the event of a power failure during operation, when the power
returns the stove cools down and then restarts automatically.
FAILED START-UP
If a flame fails to ignite during the start-up phase, the stove alarm
is triggered.