PELLET STOVES
Chapter 2
USE AND MAINTENANCE MANUAL
page
11
Theoretical recommendations for installation
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
MCZ strongly recommends the use of certified fuel in
its stoves (DINplus
and
Ö-Norm M7135).
Using poor quality pellets or pellets that do not
comply with the indications given above
compromises the operation of your stove and may
consequently lead to decline of the guarantee and
liability for the product.
MCZ pellet stoves operate only with pellets of 5 mm
to max. 30 mm length and 6 mm diameter (in ITALY
only) or 6-8 mm diameter (in other European
countries).
2.2.
INSTALLATION PRECAUTIONS
IMPORTANT!
The stove must be installed and assembled by
qualified staff.
The stove must be installed in a suitable place to allow normal opening
and regular maintenance.
The room in which the stove is installed must:
offer the correct environmental conditions for operation
be equipped with a 230V 50 Hz electrical power supply
offer a suitable smoke outlet system
be fitted with external ventilation
be fitted with an EC-compliant earthing system
The stove must be connected to a flue pipe or internal or
external vertical duct, in accordance with the applicable
standards in force.
The stove must be positioned so that the electrical plug is
accessible.
IMPORTANT!
The stove must be connected to a flue pipe or a
vertical duct that can discharge the smoke at the
highest point of the home.
The smoke does, however, result from combustion of
wood essences and may therefore soil walls if
released in contact with or close to them.
Caution: the smoke is not very visible but is very hot
and can cause burns on contact
.
Before positioning the stove, holes must be made for
the smoke pipe passage and the external air inlet.
2.3.
THE OPERATING ENVIRONMENT
For correct functioning and even distribution of heat, the stove should
be positioned in a location in which the air required for pellet
combustion can flow in (approximately 40 m
3
/h must be available), in
accordance with the installation regulations and applicable standards in
force in the country of installation.
The volume of the room should be no less than 30 m
3
.