PELLET STOVES
Chapter 4
USE AND MAINTENANCE MANUAL
page
38
Operation
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
4.9.
THE HOT AIR FAN
4.9.1.
Menu navigation
To navigate the menu headings press button 6 repeatedly. You can
make modifications using button 5. If you press button 3 quickly or
simply wait 7 seconds the remote control will exit the menu heading
and confirm any modifications.
4.9.2.
COMFORT AIR version
In this version, the stoves are equipped with two fans which duct the
hot air at the front and rear. Conventionally, we will refer to
“fan 1”
as
the one releasing air at the front and to
“fan 2”
as the one with the
rear outlet. Adjustment of the two fans (summarised in the table
below) is independent and is set via the control panel.
Type Fan
speed
Fan 1
0 1 2 3 4 5
Fan 2
0 1 2 3 4 5
35 POSSIBLE COMBINATIONS
COMBINATION 0-0 IS NOT PERMITTED
The procedure is similar to the AIR version. Enable the fan icon via
button (
6
)
on the remote control. Above the bar symbol (
17
) indicating
the fan speed, number 1 will appear. This indicates that you are
programming "fan 1". Adjust the intensity via button (
5
) Press button
(
6
). Number 2 will appear above the bars. This indicates that you are
programming "fan 2". Adjust the intensity via button (
5
)
If the keypad is not pressed for 7 seconds the remote
control automatically exits fan adjustment mode and
confirms the most recent setting entered.
If low fan settings are selected the power of the
stove will be automatically limited to prevent the
structure and the air released by the room fans from
overheating.
6
5