DS80C400 Network Microcontroller
66 of 96
NOCRS, No Carrier.
This bit is only valid in half-duplex mode.
0 = transmit frame was not aborted due to lack of carrier
1 = transmit frame aborted due to lack of carrier (CRS = 0 when transmit frame initiated)
JABTO, Jabber Timeout
0 = transmit frame was not aborted due to jabber timeout
1 = transmit frame aborted due to jabber timeout (MAC transmitter has been active for twice the Ethernet max
frame length)
ABORT
,
Frame Aborted
0 = transmit frame was not aborted
1 = transmit frame was aborted by the MAC due to one of the following conditions: jabber timeout, no carrier, loss
of carrier, excessive deferral, late collision, retry count exceeds the attempt limit, and data underrun
Receive Status Word
Bit Names:
31
MF
PF
FF
BCF MCF UCTRL CTRL LEN 24
23 VLAN2
VLAN1 CRC DRIB
MII_ER TYPE COL LONG 16
15 RUNT
WDOG
FLEN
[13:8]
8
7 FLEN
[7:0]
0
MF, Missed Frame
0 = receive frame was not missed
1 = receive frame missed
PF, Packet Filter
0 = current frame failed the packet filter
1 = current frame passed the packet filter
FF, Filter Fail
0 = destination address of the current receive frame passed the applied address filter
1 = destination address of the current receive frame failed the applied address filter
BCF, Broadcast Frame
0 = receive frame is not a broadcast frame
1 = receive frame is a broadcast frame (i.e., destination address is all ones)
MCF
,
Multicast Frame
0 = receive frame is not a multicast frame
1 = receive frame is a multicast frame (i.e., first bit of the destination address is a 1)
UCTRL,
Unsupported Control Frame.
This bit is only valid in full-duplex mode.
0 = receive frame is not an unsupported control frame
1 = receive frame is a control frame that is not supported (i.e., one that contains an op code field that is not
supported or one that is not equal to the 64-Byte minimum frame size)
CTRL, Control Frame.
This bit is only valid in full-duplex mode.
0 = receive frame is not a control frame
1 = receive frame is a control frame
LEN,
Length Error.
The frame length check is performed only when type/length field contains frame length (TYPE
= 0). When the data field contains more bytes than specified in the length field, these bytes are assumed to be pad
bytes.
0 = receive frame passed the frame length check
1 = receive frame contained fewer bytes than specified in the length field
Содержание DS80C400
Страница 6: ...DS80C400 Network Microcontroller 6 of 96...
Страница 7: ...DS80C400 Network Microcontroller 7 of 96...
Страница 15: ...DS80C400 Network Microcontroller 15 of 96...
Страница 16: ...DS80C400 Network Microcontroller 16 of 96 l...
Страница 22: ...DS80C400 Network Microcontroller 22 of 96 OW PIN TIMING...